Rack
and Pinion
Actuators

Engineered
for quality and
excellence.

Double Acting Actuators

Air to Port A forces the pistons outwards, causing the pinion to turn counterclockwise while the air is being exhausted from Port B.

 

Air to Port B forces the pistons inwards, causing the pinion to turn clockwise while the air is being exhausted from Port A.

Air to Port A forces the pistons outwards, causing the pinion to turn clockwise while the air is being exhausted from Port B.

 

Air to Port B forces the pistons inwards, causing the pinion to turn counterclockwise while the air is being exhausted from Port A.

Spring Return Actuators

Air to port A forces the pistons outwards, causing the springs to compress, The pinion turns counterclockwise while air is being exhausted from port B.

 

Loss of air pressure on port A causes the stored energy in the springs to force the pistons inwards. The pinion turns clockwise while air is being exhausted from port A.

Air to Port A forces the pistons outwards, causing the pinion to turn clockwise while the air is being exhausted from Port B.

 

Loss of air pressure on port A causes the stored energy in the springs to force the pistons inwards. The pinion turns counterclockwise while air is being exhausted from port A.